Publication Date:
2022
abstract:
The scenario integrated modelling is a top priority work during
the design of a new tokamak, as the Divertor Tokamak Test facility (DTT) under
construction at the ENEA Research Center in Frascati. The first simulations of
the main baseline scenarios contributed to the optimization of the DTT project,
particularly with regard to the machine size and heating systems, besides serving as
reference for diagnostics design. In this paper we report the first simulations of the
full power baseline scenario in the final configuration of the machine and heating
mix.
Iris type:
01.01 Articolo in rivista
Keywords:
Divertor Tokamak Test Facility; DTT
List of contributors:
Mariani, Alberto; Granucci, Gustavo; Innocente, Paolo; Figini, Lorenzo; Agostinetti, Piero; Baiocchi, Benedetta; Valisa, Marco; Mantica, Paola
Published in: