Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Electrochemical sensor based on r-GO/Au nanoparticles for monitoring H2O2 released by human macrophages

Academic Article
Publication Date:
2020
abstract:
Increased oxidative burden contributes to the pathogenesis of most inflammatory diseases and is associated with aging and chronic inflammation. Macrophages contribute to the generation of reactive oxygen species (ROS) within inflamed tissues. Currently, ROS generation is measured using fluorescent probes and colorimetric/fluorimetric biochemical assays. Hydrogen peroxide (H2O2) diffuses through the cell membrane and can be monitored in the extracellular space. Herein, we present a sensor for H2O2 detection released by cells in culture supernatants. H2O2 sensing Journal Pre-proof performance was evaluated using chronoamperometric detection. A sensitivity of 0.0641 ?A ?M-1 cm-2 with a limit of detection of 6.55 ?M and excellent selectivity against many interferents was found. H2O2 release was also measured in conditioned medium from human THP-1 macrophages exposed to pro-oxidant and anti-oxidant treatments. The results were compared with those obtained by flow cytometry using the same cells stained with carboxy-H2DCFDA and MitoSOX Red, which detected intracellular ROS and mitochondrial superoxide, respectively. The addition of LPS and nigericin resulted in a significant increase in the cathodic current due to the H2O2 reduction, indicating an increased release of H2O2. The addition of 17-oxo-DHA, which inhibits LPS- and nigericin-dependent responses, decreased the LPS- and nigericin-induced release of H2O2. All the results obtained with the sensor were consistent with those obtained using flow cytometry. The operation of the sensor directly in the cell culture growth medium had no impact on cell viability. The sensor is highly sensitive, fast, and cost effective, and it can potentially be used for real time monitoring of oxidative stress.
Iris type:
01.01 Articolo in rivista
Keywords:
Electrochemical sensor; Oxidative stress; Macrophages
List of contributors:
Pace, Elisabetta; Ferraro, Maria; DI VINCENZO, Serena
Authors of the University:
DI VINCENZO SERENA
FERRARO MARIA
PACE ELISABETTA
Handle:
https://iris.cnr.it/handle/20.500.14243/392113
Published in:
SENSORS AND ACTUATORS. B, CHEMICAL
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)