Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Standardized guidelines for the interpretation of dobutamine echocardiography reduce interinstitutional variance in interpretation

Academic Article
Publication Date:
1998
abstract:
Subjective interpretation of dobutamine echocardiograms provides only moderate interinstitutional observer agreement if nonunified data acquisition and assessment criteria are applied. The present study was undertaken to evaluate parameters associated with low interinstitutional observer agreement in the interpretation of dobutamine echocardiograms and to analyze whether standardized interpretation criteria improve interinstitutional observer agreement. One hundred fifty dobutamine echocardiograms (dobutamine up to 40 mu g/kg/min body weight and atropine up to 1 mg) were evaluated at 5 centers. Clinical, procedural, and echocardiographic parameters were included in the analysis of variables with significant impact on interinstitutional agreement Standardized interpretative criteria were established, and 90 dobutamine echocardiograms were reanalyzed by 3 observers using a standardized Image display. Multivariate analysis demonstrated low image quality (odds ratio [OR] 0.19, 95% confidence interval [CI] 0.08 to 0.45, p = 0.0002), low severity of induced wall motion abnormality (OR 0.17, 95% CI 0.07 to 0.40, p <0.0001), and a low peak rate-pressure product (OR 0.93, 95% CI 0.43 to 2.27, p = 0.0382) to result in a low interinstitutional agreement. Standardization of image display in cine loop format and of dobutamine stress echo interpretation criteria resulted in improvement in test result categorization as normal or abnormal, with a kappa value of 0.50, compared with 0.39 using the original subjective interpretation. In conclusion, image quality, the severity of induced wall motion abnormalities, and the obtained rate-pressure product have a significant impact on the interpretation homogeneity of dobutamine echocardiograms. Standardization of image display in cine loop format and of reading criteria results in improved interinstitutional agreement in interpretation of stress echocardiograms. (C) 1998 by Excerpta Medica, Inc.
Iris type:
01.01 Articolo in rivista
Keywords:
Stress echocardiography; dobutamine
List of contributors:
Picano, Eugenio; Pingitore, Alessandro
Authors of the University:
PINGITORE ALESSANDRO
Handle:
https://iris.cnr.it/handle/20.500.14243/411840
Published in:
THE AMERICAN JOURNAL OF CARDIOLOGY
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)