Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

One year of downwelling spectral radiance measurements from 100 to 1400 cm(-1) at Dome Concordia: Results in clear conditions

Academic Article
Publication Date:
2016
abstract:
The present work examines downwelling radiance spectra measured at the ground during 2013 by a Far Infrared Fourier Transform Spectrometer at Dome C, Antarctica. A tropospheric backscatter and depolarization lidar is also deployed at same site, and a radiosonde system is routinely operative. The measurements allow characterization of the water vapor and clouds infrared properties in Antarctica under all sky conditions. In this paper we specifically discuss cloud detection and the analysis in clear sky condition, required for the discussion of the results obtained in cloudy conditions. First, the paper discusses the procedures adopted for the quality control of spectra acquired automatically. Then it describes the classification procedure used to discriminate spectra measured in clear sky from cloudy conditions. Finally a selection is performed and 66 clear cases, spanning the whole year, are compared to simulations. The computation of layer molecular optical depth is performed with line-by-line techniques and a convolution to simulate the Radiation Explorer in the Far InfraRed-Prototype for Applications and Development (REFIR-PAD) measurements; the downwelling radiance for selected clear cases is computed with a state-of-the-art adding-doubling code. The mean difference over all selected cases between simulated and measured radiance is within experimental error for all the selected microwindows except for the negative residuals found for all microwindows in the range 200 to 400cm(-1), with largest values around 295.1cm(-1). The paper discusses possible reasons for the discrepancy and identifies the incorrect magnitude of the water vapor total absorption coefficient as the cause of such large negative radiance bias below 400cm(-1).
Iris type:
01.01 Articolo in rivista
Keywords:
far infrared; Dome C; water vapor continuum
List of contributors:
DEL GUASTA, Massimo; Palchetti, Luca; Bianchini, Giovanni
Authors of the University:
BIANCHINI GIOVANNI
DEL GUASTA MASSIMO
PALCHETTI LUCA
Handle:
https://iris.cnr.it/handle/20.500.14243/356499
Published in:
JOURNAL OF GEOPHYSICAL RESEARCH. ATMOSPHERES (PRINT)
Journal
  • Overview

Overview

URL

http://www.scopus.com/inward/record.url?eid=2-s2.0-84991257143&partnerID=q2rCbXpz
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)