INFLUENCE OF OPERATING CONDITIONS ON THE PERFORMANCE OF AN ANION EXCHANGE MEMBRANE ELECTROLYSER
Contributo in Atti di convegno
Data di Pubblicazione:
2022
Abstract:
In this work, a FAA3-50 anion-exchange membrane (from FuMa-Tech) has been used,
after exchange in KOH solution (1 M), as electrolyte/separator in a single cell of 5 cm2
geometrical area. In the first approach, commercial IrO2 and 40% Pt/C catalysts have
been used at the anode and cathode, respectively, to evaluate the membrane under the
most convenient conditions. The influence of cell temperature, membrane-electrode
assembly (MEA) procedure (catalyst-coated membrane or catalyst coated electrode),
ionomer content in the electrodes, use of pure water or KOH solution, on electrolyser
performance have been analysed.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Keywords:
Water electrolysis
Elenco autori:
Patti, Assunta; Monforte, Giuseppe; Baglio, Vincenzo; Gatto, Irene; Trocino, Stefano; LO VECCHIO, Carmelo; CAMPAGNA ZIGNANI, Sabrina
Link alla scheda completa: