Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Phase I-II studies on accelerated IMRT in breast carcinoma: Technical comparison and acute toxicity in 332 patients

Academic Article
Publication Date:
2009
abstract:
Background and purpose: To evaluate the results in terms of dosimetric parameters and acute toxicity of two clinical studies (MARA-1 and MARA-2) on accelerated IMRT-based postoperative radiotherapy. These results are compared with historical control group (CG) of patients treated with "standard" 3D postoperative radiotherapy. Materials and methods: Prescribed dose to the breast was 50.4 Gy in the CG, 40 Gy in MARA-1 (low risk of local recurrence), and 50 Gy in MARA-2 (medium-high risk of recurrence). The tumor bed total dose was 60.4 Gy (sequential 10 Gy electron boost), 44 Gy (concomitant 4 Gy boost), and 60 Gy (concomitant 10 Gy boost) in CG, MARA-1 and MARA-2 studies, respectively. Overall treatment time was of 32 fractions for CG (6.4 weeks); 16 fractions for MARA-1 study (3.2 weeks) and 25 fractions for MARA-2 study (5 weeks). Results: Three hundred and thirty two patients were included in the analysis. Dosimetric analysis showed D and V reduction (p < 0.001) and D improvement (p < 0.001) in the PTV in patients treated with IMRT. Grade 2 acute skin toxicity was 33.6%, 13.1%, and 45.1% in the CG, MARA-1, and MARA-2, respectively (p < 0.001), and grade 3 acute skin toxicity was 3.1%, 1.0%, and 2.0%, respectively. Similarly, larger PTV and use of chemotherapy with anthracyclines and taxanes were associated with a greater acute toxicity. With a median follow-up of 31 months, no patients showed local or nodal relapse. Conclusions: A simplified step and shoot IMRT technique allowed better PTV coverage and reduced overall treatment time (CG, 6.6 weeks; MARA-1, 3.2 weeks; MARA-2, 5 weeks) with acceptable short-term toxicity. © 2008 Elsevier Ireland Ltd. All rights reserved.
Iris type:
01.01 Articolo in rivista
Keywords:
Acute toxicity; Breast cancer; Dosimetry; IMRT
List of contributors:
DE GAETANO, Andrea; Panunzi, Simona
Authors of the University:
DE GAETANO ANDREA
PANUNZI SIMONA
Handle:
https://iris.cnr.it/handle/20.500.14243/439758
Published in:
RADIOTHERAPY AND ONCOLOGY
Journal
  • Overview

Overview

URL

http://www.scopus.com/record/display.url?eid=2-s2.0-58149477702&origin=inward
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)