Spectral ultraviolet measurements by a multichannel monitor and a Brewer spectroradiometer: a field study

Academic Article
Publication Date:
2002
abstract:
Two different instruments for measuring the spectral UV irradiance were used in a field comparison study in July 2000 in Rome, Italy: a Brewer spectrophotomenter and a moderate-bandwith filter radiometer (GUV-511C). The Brewer is designed to measure the solar spectral irradiances in the region from 290 nm to 325 nm with a spectral resolution 0.5 nm. The GUV- 511C measures band-averaged spectral irradiance at four wavelengths:305,320,340 and 380 nm with a bandwith depending on the filter type for each channel (about 10 nm full width half maximum,FWHM). Comparisons between the two instruments were made for 5 days for the two wavelengths 305 and 320 nm under different meteorological conditions with the Brewer taken as the reference.