Seismic assessment of precast beam-to-column connections and retrofitting solutions
Conference Paper
Publication Date:
2017
abstract:
The inadequacy of beam-to-column connections in RC precast structures can cause catastrophic collapses due, for instance,
to loss of support phenomena in the case of absence of mechanical devices. In order to achieve an adequate global seismic
capacity, hence, the retrofitting of these connections is a necessary step for existing precast structures.
An experimental campaign is performed in order to investigate the seismic behavior of typical beam-to-column
connections for precast one-story buildings.
The reference connection is a dowel beam-to-column connection, tested under cyclic shear loads up to collapse. It
showed a very brittle failure with concrete cover splitting in the column and a non-symmetric behavior for the two loading
directions. In particular, for pulling loads (i.e. horizontal loads against the column frontal cover) a significant strength
degradation occurs after the attainment of the maximum shear strength, corresponding to the occurrence of the first crack in
the column concrete cover.
After the cyclic shear test, the described beam-to-column connection was retrofitted. The proposed retrofitting
solution is based on two main mechanical principles: the three hinged arch and the dowel effect so that the total seismic
force applied to the beam is transferred to the other two hinges on the column by two steel profiles. The cyclic global
behavior in terms of force-displacement curve was investigated and the damage patterns after the test were described by
means of both visual inspections and instrumentation records.
The experimental results demonstrate a good behavior under seismic actions, since no significant damage in the
concrete was recorded due to the large concrete covers in the retrofitted system which prevented brittle failures in the
connected elements. The horizontal shear force was mostly sustained by the three hinges mechanism, ensured by the two
steel profiles under axial loads.
Moreover, the comparison between the retrofitted and the dowel beam-to-column connection also allow to define the
main critical features of this connection system, as the concrete cover of steel bars in the connected structural elements. The
retrofitted conn