Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Calibration and functional analysis of three genetically encoded Cl(-)/pH sensors.

Academic Article
Publication Date:
2013
abstract:
Monitoring of the intracellular concentrations of Cl(-) and H(+) requires sensitive probes that allow reliable quantitative measurements without perturbation of cell functioning. For these purposes the most promising are genetically encoded fluorescent biosensors, which have become powerful tools for non-invasive intracellular monitoring of ions, molecules, and enzymatic activity. A ratiometric CFP/YFP-based construct with a relatively good sensitivity to Cl(-) has been developed (Markova et al., 2008; Waseem et al., 2010). Recently, a combined Cl(-)/pH sensor (ClopHensor) opened the way for simultaneous ratiometric measurement of these two ions (Arosio et al., 2010). ClopHensor was obtained by fusion of a red-fluorescent protein (DsRed-monomer) to the E(2)GFP variant that contains a specific Cl(-)-binding site. This construct possesses pK a = 6.8 for H(+) and K d in the 40-50 mM range for Cl(-) at physiological pH (~7.3). As in the majority of cell types the intracellular Cl(-) concentration ([Cl(-)] i ) is about 10 mM, the development of sensors with higher sensitivity is highly desirable. Here, we report the intracellular calibration and functional characterization of ClopHensor and its two derivatives: the membrane targeting PalmPalm-ClopHensor and the H148G/V224L mutant with improved Cl(-) affinity, reduced pH dependence, and pK a shifted to more alkaline values. For functional analysis, constructs were expressed in CHO cells and [Cl(-)] i was changed by using pipettes with different Cl(-) concentrations during whole-cell recordings. K d values for Cl(-) measured at 33°C and pH ~7.3 were, respectively, 39, 47, and 21 mM for ClopHensor, PalmPalm-ClopHensor, and the H148G/V224L mutant. PalmPalm-ClopHensor resolved responses to activation of Cl(-)-selective glycine receptor (GlyR) channels better than did ClopHensor. Our observations indicate that these different ClopHensor constructs are promising tools for non-invasive measurement of [Cl(-)] i in various living cells.
Iris type:
01.01 Articolo in rivista
List of contributors:
Arosio, Daniele
Authors of the University:
AROSIO DANIELE
Handle:
https://iris.cnr.it/handle/20.500.14243/282235
Published in:
FRONTIERS IN MOLECULAR NEUROSCIENCE
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)