Enhanced Fluorescence in a Lens-Less Fiber-Optic Sensor for C-Reactive Protein Detection

Academic Article
Publication Date:
2023
abstract:
In today's medicine, the celerity of the bio-assays analysis is crucial for the timely selection of the appropriate therapy and hence its effectiveness, especially in case of diseases characterized by the late onset of symptoms. In this paper, a lens-less fiber optics-based fluorescence sensor designed for the measurement of labeled bio-assays is presented and its potential for the early diagnosis of sepsis via C-reactive protein (CRP) detection is demonstrated. The sensor performance results from the combination of two key elements: a planar antenna that redirects fluorescence the marker emission and an automated fiber-based optical system for multi-spot analysis. First, the working principle of the device is demonstrated with a well-established antibody-antigen format (immunoglobulin IgG/anti-IgG assay), reporting more than one order of magnitude enhanced limit of detection (LOD) and limit of quantification (LOQ) for the planar antenna with respect to a standard glass substrate. The prototype is then tested against a sample mimicking a realistic case, prepared with commercially available human serum, showing a LOD and LOQ in the clinical range of interest (0.0015 ?g/mL and 0.005 ?g/mL, respectively) for the investigation of the sepsis biomarker CRP. These results validate the developed prototype as a simple and easy-to-operate device, compatible with standardized micro-well arrays, and potentially suitable for POC applications.
Iris type:
01.01 Articolo in rivista
Keywords:
ens-less light collection; fiber-based sensor; protein biomarker
List of contributors:
Majumder, Prosenjit; ESTESO CARRIZO, Victoria; Giannetti, Ambra; Toninelli, Costanza; Chiavaioli, Francesco; Lombardi, PIETRO ERNESTO; Colautti, Maja; Baldini, Francesco
Authors of the University:
BALDINI FRANCESCO
CHIAVAIOLI FRANCESCO
COLAUTTI MAJA
GIANNETTI AMBRA
LOMBARDI PIETRO ERNESTO
TONINELLI COSTANZA
Handle:
https://iris.cnr.it/handle/20.500.14243/450507
Published in:
CHEMOSENSORS