System for temperature and power flux measurements on the RFX first wall

Academic Article
Publication Date:
1999
abstract:
A thermal imaging system has been installed on the RFX at Consorzio RFX to investigate the phenomenology of the plasma wall interactions. The infrared camera, model Amber AE4128, is based on a 128×128 InSb focal plane array detector and operates in the range of 4.5-5 ?m with an acquisition rate of 217 Hz and 12 bit of dynamic range. The system, absolutely calibrated, is sensitive from room temperature up to 3000 °C, with different setups. The experimental data are compared with the numerical results obtained by means of transient thermal analyses carried out on analytical and finite element models of a graphite tile.
Iris type:
01.01 Articolo in rivista
List of contributors:
Valisa, Marco; Zaccaria, Pierluigi; Pasqualotto, Roberto
Authors of the University:
PASQUALOTTO ROBERTO
VALISA MARCO
Handle:
https://iris.cnr.it/handle/20.500.14243/192380
Published in:
REVIEW OF SCIENTIFIC INSTRUMENTS