Skip to Main Content (Press Enter)

Logo CNR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze

UNI-FIND
Logo CNR

|

UNI-FIND

cnr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Strutture
  • Competenze
  1. Pubblicazioni

Post-exercise contractility, diastolic function, and pressure: Operator-independent sensor-based intelligent monitoring for heart failure telemedicine

Articolo
Data di Pubblicazione:
2009
Abstract:
Background: New sensors for intelligent remote monitoring of the heart should be developed. Recently, a cutaneous force-frequency relation recording system has been validated based on heart sound amplitude and timing variations at increasing heart rates. Aim: To assess sensor-based post-exercise contractility, diastolic function and pressure in normal and diseased hearts as a model of a wireless telemedicine system. Methods: We enrolled 150 patients and 22 controls referred for exercise-stress echocardiography, age 55 ± 18 years. The sensor was attached in the precordial region by an ECG electrode. Stress and recovery contractility were derived by first heart sound amplitude vibration changes; diastolic times were acquired continuously. Systemic pressure changes were quantitatively documented by second heart sound recording. Results: Interpretable sensor recordings were obtained in all patients (feasibility = 100%). Postexercise contractility overshoot (defined as increase 10% of recovery contractility vs exercise value) was more frequent in patients than controls (27% vs 8%, p 0.05). At 100 bpm stress heart rate, systolic/diastolic time ratio (normal, 1) was 1 in 20 patients and in none of the controls (p 0.01); at recovery systolic/diastolic ratio was 1 in only 3 patients (p 0.01 vs stress). Postexercise reduced arterial pressure was sensed. Conclusion: Post-exercise contractility, diastolic time and pressure changes can be continuously measured by a cutaneous sensor. Heart disease affects not only exercise systolic performance, but also post-exercise recovery, diastolic time intervals and blood pressure changes - in our study, all of these were monitored by a non-invasive wearable sensor.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Heart failure
Elenco autori:
Faita, Francesco; Sicari, Rosa; Pratali, Lorenza; Giannoni, Massimo; Gemignani, Vincenzo; Picano, Eugenio
Autori di Ateneo:
FAITA FRANCESCO
GEMIGNANI VINCENZO
GIANNONI MASSIMO
PRATALI LORENZA
SICARI ROSA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/74390
Pubblicato in:
CARDIOVASCULAR ULTRASOUND
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)