Unmanned aerial vehicle equipped with spectroscopic CdZnTe detector for detection and identification of radiological and nuclear material
Contributo in Atti di convegno
Data di Pubblicazione:
2015
Abstract:
Localization and identification of nuclear and radiological material are main issues in case of nuclear accident or terrorist attack. In these cases, the use of a unmanned aerial vehicle would be highly recommended in order to preserve the safety of the human operators. For this purpose, we have integrated a compact, light, low power operating, CZT-based gamma ray detector on a commercially available UAV. The system allows exploration of potentially dangerous areas without a close exposure of the human operator. The operator is able to provide motion commands to the UAV while receiving force feedback from a 3DOF haptic interface. Force feedback provides an attractive basin around the location of the most intense detected radiation. A field experiment has been carried out and a 192Ir nuclear source has been localized and identified exploiting the novel teleoperation system.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Keywords:
feedback; gamma rays; haptic interfaces; medical imaging; radioactive materials; unmammed aerial vehicles (UAV)
Elenco autori:
Zanichelli, Massimiliano; Bettelli, Manuele; Zappettini, Andrea; Calestani, Davide
Link alla scheda completa:
Titolo del libro:
2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC)
Pubblicato in: