1950°C annealing of Al+ implanted 4H-SiC: Sheet resistance dependence on the annealing time

Conference Paper
Publication Date:
2016
abstract:
This study shows that, after annealing at 1950°C, a 1×1020 cm Al implanted 4H-SiC material shows a decreasing resistivity with increasing annealing time in the range 5-25 min. After this, the resistivity remains constant up to an annealing time of 40 min. The estimated minimum time to gain the thermal equilibrium in this implanted material at 1950°C is 12 min. Electrical characterization has been performed in the 20-680 K temperature range.
Iris type:
04.01 Contributo in Atti di convegno
Keywords:
4H-SiC; Al doping by ion implantation; Post implantation annealing time