Using microwave network analyzer and MSW-SER to measure linewidth spectrum in magnetic garnet film from 0.5 to 20 GHz

Articolo
Data di Pubblicazione:
1993
Abstract:
A measurement technique, based on the combination of a modern network analyzer and wideband-tunable magnetostatic wave straight-edge resonators (MSW-SER), is taken to automatically measure the linewidth (?H) in yttrium ion garnet (YIG) epilayers at 0. 5-20 GHz. Smith chart and voltage standing wave ratio method are used to determine the half resonance band (??). ?H value is calculated from ?? using resonance conditions of MSW-SERs. A system with insertion loss <0.07 dB and return < - 50dB is set up by an improved calibration. Four pieces of YIG films with thickness 9-120?m and magnetization 370-1750 Gs are examined in 0.5-20 GHz. The results measured at 9. 2 GHz agree well with those obtained by ferromagnetic resonance.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Ferromagnetic Resonance; Calibration; Network Analyzer
Elenco autori:
DE GASPERIS, Paolo; Marcelli, Romolo
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/206904
Pubblicato in:
IEEE TRANSACTIONS ON MAGNETICS