Novel fiber tip sensor potentially suitable for gastric pH measurement
Contributo in Atti di convegno
Data di Pubblicazione:
2011
Abstract:
Monitoring pH for long periods, usually 24 h, in the stomach and in the esophagus may be essential in the diagnosis of gastro-esophageal diseases. The clinical range of interest is quite extended, between 1 to 8 pH units. Methyl red, after its covalent immobilization on controlled pore glass (CPG), is characterized by a working range which fits well with the clinical one. A novel probe, suitable for gastro-esophageal applications, was designed in order to optimize the performances of the colored CPG. This leads to a very simple probe configuration characterized by a very fast response.
Tipologia CRIS:
04.01 Contributo in Atti di convegno
Elenco autori:
Ghini, Giacomo; Senesi, Folco; Giannetti, Ambra; Trono, Cosimo; Baldini, Francesco
Link alla scheda completa: