Publication Date:
2005
abstract:
This paper presents the results of the design investigations and the manufacturing of cryosorption pumps for the Neutral Beam
Test Facility 'MANITU' at Max Planck Institute for Plasma Physics (IPP) and the cryopump design analyses performed for the
development of a test facility for the first ITER Neutral Beam Injector.
The two identical cryopumps for IPP are foreseen to pump a hydrogen-throughput of 3 Pam3/s (H2) with a pumping speed of
350m3/s per pump. The pressure conditions must be maintained over 4 h pumping without regeneration of the cryopanels. For
the ITER Neutral Beam Test Facility, design calculations to assess heat loads and pumping parameters of the cryopumps will be
briefly described
Iris type:
01.01 Articolo in rivista
Keywords:
Cryopump; Cryosorption; Heat load; Neutral Beam Injector
List of contributors:
Zaccaria, Pierluigi
Published in: