abstract:
Water is a common fundamental resource for life. The effects of climate change, pollution and waste make it an increasingly scarce resource. Therefore, it becomes very important to monitor water quality to identify situations of possible harm to humans. In this study, incoming wastewater of the depuration plant of A2A Ciclo Idrico in Brescia has been analyzed with an array of MOX nanowire gas sensors. In addition, GC-MS technique has been used to relate sensors responses with the emitted VOCs of the samples. The ability of the system to recognize potable water from wastewater and chemically contaminated wastewater has been found. PCA and ANN methods have been employed in order to see how samples classes cluster and to assess the capability of the device to classify them properly,respectively.
Iris type:
01.01 Articolo in rivista
Keywords:
nanowire gas sensors; multivariate analysis; environmental monitoring
List of contributors:
Sberveglieri, Veronica; NUNEZ CARMONA, Estefania
Authors of the University:
NUNEZ CARMONA ESTEFANIA
SBERVEGLIERI VERONICA
Handle:
https://iris.cnr.it/handle/20.500.14243/353353
Published in:
PROCEEDINGS (MDPI)