A simplified thermal CFD approach to fins and tube heat exchanger: Application to maldistributed airflow on an open display cabinet

Academic Article
Publication Date:
2015
abstract:
Airflow maldistribution in heat exchangers and air channels is a common problem in HVAC&R systems. Furthermore, in the refrigeration field, temperature and velocity maldistribution downstream the evaporator can reach the discharge air grille, negatively influencing the heat removal from the exposed goods. In the present paper, the effect of the flow maldistribution in the air channel of an open refrigerated display cabinet is studied by means of computational fluid dynamics simulations. An equivalent thermal approach is presented: in combination with the equivalent resistance approach, it allows a drastic reduction of computational effort. This thermal CFD model allows to evaluate the 3D effects of the maldistribution in terms of temperature, heat transfer coefficients, and cooling power in the full channel model. Discussion of the results is reported. (C) 2015 Elsevier Ltd and IIR. All rights reserved.
Iris type:
01.01 Articolo in rivista
Keywords:
Air distribution; Heat exchanger; Simulation; Display cabinet; Computational fluid dynamics; Heat transfer
List of contributors:
Marinetti, Sergio; Minetto, Silvia; Rossetti, Antonio
Authors of the University:
MARINETTI SERGIO
MINETTO SILVIA
ROSSETTI ANTONIO
Handle:
https://iris.cnr.it/handle/20.500.14243/307451
Published in:
INTERNATIONAL JOURNAL OF REFRIGERATION
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)