Real-time aerosol photometer and optical particle counter comparison

Academic Article
Publication Date:
2010
abstract:
The paper presents the results of a comparison exercise among real-time aerosol samplers, based on different light scattering techniques. The comparison was carried out near to the ISAC institute in a box positioned inside the CNR research area in Bologna. Two nephelometers (DustTrak from TSI, and Air Genius from Unitec) and an optical particle counter (ENVIRO-check from Grimm) were used for PM1 and PM10 fraction assessment. In the case of the optical particle counter, the particle number concentration in each size bin was also used. In parallel, two manual sampling lines were employed for reference (gravimetric) measurements. The results highlight different factor scales for the dust monitors, in comparison with gravimetric assessment, underlining the importance of a user calibration of such monitors as a function of the specific aerosol sampled. Moreover, the relative fluctuations of the hourly PM10 and PM1 concentrations, against daily average concentrations, were studied in order to compare the ability of each sampler to follow changes in the aerosol size distribution. It was found that the photometers and optical particle counter revealed different behaviours. In the latter, a small increase in the particle concentration number in the coarse fraction gave a relatively high increase in the mass concentration that was not measured by the photometers. The explanation could be the relatively slight influence of a small particle number variation on the total scattered light for the photometers, unlike the case of the optical particle counter, where each particle contributes to the mass concentration. This aspect merits future research in order to better understand optical particle counter output used in PMx monitoring activities.
Iris type:
01.01 Articolo in rivista
Keywords:
aerosol; opc; fotometria
List of contributors:
Prodi, Franco; Santachiara, Gianni; Belosi, Franco
Authors of the University:
BELOSI FRANCO
Handle:
https://iris.cnr.it/handle/20.500.14243/41289
Published in:
IL NUOVO CIMENTO B
Journal