Sleep structure correlates of continuous positive airway pressure variations during application of an autotitrating continuous positive airway pressure machine in patients with obstructive sleep apnea syndrome

Articolo
Data di Pubblicazione:
2002
Abstract:
Study Objectives: To evaluate the relationship between sleep structure and continuous positive airway pressure (CPAP) delivered by an automatic CPAP (autoCPAP) machine in obstructive sleep apnea syndrome (OSAS). Design: Nocturnal polysomnography was performed during CPAP administration by an autoCPAP machine (Autoset Clinical 1, Rescare, Sydney, Australia). Setting: Sleep disorders center in a research Institute. Patients: Fifteen subjects with newly diagnosed OSAS deserving home CPAP treatment. Measurements and results: During the night, in most cases the lowest CPAP level was recorded during a prolonged NREM sleep period uninterrupted by arousals, whereas the highest level during wake-sleep transitions or NREM sleep fragmented by arousals. In four subjects REM sleep was always associated with increasing CPAP. Sleep efficiency was negatively correlated with CPAP variability, evaluated as the SD of the mean nocturnal CPAP level averaged epoch by epoch (r = 0.63, p<0.02). Eighty-eight percent of rapid CPAP augmentations (increases by at least 2 cm H2O in £2 minutes) were observed during sleep-wake transitions or after arousals or awakenings; 63% of such arousals and awakenings were not preceded by any detectable respiratory abnormality. Conclusions: CPAP levels and variations during autoCPAP application may be mainly related to sleep continuity and efficiency. The recording of a highly variable pressure during autoCPAP administration in an unattended environment must raise the question whether the patient’s sleep quality was acceptable. A poor sleep quality during an autotitration night could lead to an undesirable overestimation of the CPAP level needed for use with fixed level CPAP machines.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
continuous positive airway pressure; obstructive sleep apnea syndrome; titration; treatment
Elenco autori:
Insalaco, Giuseppe; Romano, Salvatore; Marrone, Oreste; Salvaggio, Adriana
Autori di Ateneo:
INSALACO GIUSEPPE
SALVAGGIO ADRIANA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/156795
Pubblicato in:
CHEST (AMER. COLL. CHEST PHYS.)
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0 | Sorgente dati: PREPROD (Ribaltamento disabilitato)