Publication Date:
2010
abstract:
In this work, two-dimensional computational fluid dynamics (CFD) simulations were run to investigate the
possibility of a link between the initial conditions and the occurrence of blowout for a parallel-plate catalytic
microcombustor. The results show that steady-state multiplicity occurs: Depending on the initial conditions,
the range of inlet gas velocities at which stable operation is attained can be enlarged to avoid blowout. It is
concluded that investigations into the thermal behavior of catalytic microcombustors have to deal with
appropriate and aware choices of the initial conditions.
Iris type:
01.01 Articolo in rivista
List of contributors:
DI BENEDETTO, Almerinda; DI SARLI, Valeria
Published in: