Data di Pubblicazione:
2009
Abstract:
We analyze heat and work fluctuations in the gravitational wave detector AURIGA, modeled as a macroscopic electromechanical oscillator in contact with a thermostat and cooled by an active feedback system. The oscillator is driven to a steady state by the feedback cooling, equivalent to a viscous force. The experimentally measured fluctuations are in agreement with our theoretical analysis based on a stochastically driven Langevin system. The asymmetry of the fluctuations of the absorbed heat characterizes the oscillators nonequilibrium steady state and reveals the extent to which a feedback cooled system departs from equilibrium in a statistical mechanics perspective.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
AURIGA; electromechanical oscillator; feedback cooling; nonequilibrium steady state; statistical mechanics
Elenco autori:
Bonaldi, Michele; Falferi, Paolo; Vinante, Andrea
Link alla scheda completa: