This work is aimed at presenting an analysis, by stereoscopic Particle Image Velocimetry
(PIV) technique, of the air speed distribution inside the cooling duct of a display cabinet and
its effect on the heat exchange efficiency. Two configurations of the duct, in which the air
is forced through the evaporator by one and two fans, respectively, are tested. 3D flow
fields, upstream and downstream the evaporator, are determined by PIV performed on
three planes containing the mainstream velocity vectors and placed at different heights.
Measurements are carried out at the maximum fan rotation rate. The analysis of the air
flow distribution at the inlet and outlet of the evaporator shows the capabilities of the PIV
technique to highlight insufficiently loaded sections of the evaporator and to estimate the
energy transfer efficiency. These results are compared with those of an ideal configuration,
in which the air flow rate is uniformly distributed at the evaporator entrance.