Abstract:
The problem of contamination during the collection of samples of environmental interest to detect trace metal is discussed. Attention is focused on the leaching of metals from sampling devices used to collect surface and deep seawater. A procedure to test metal release is applied to emphasize the importance of conditioning samplers before use. The procedure for checking the contamination extent and decontamination of firn and ice cores to detect ultratrace elements (particularly Cd and Pb) is presented and applied to some firn cores collected in Antarctica during the 1990-1991 Italian expedition.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Cadmium; Differential pulse anodic stripping voltammetry; Lead; Quality assurance; Sampling; Seawater; Snow
Elenco autori:
Turetta, Clara; Barbante, Carlo
Link alla scheda completa: