Publication Date:
2008
abstract:
Tapping mode atomic force microscopy provides good resolution in imaging applications, but it still requires a time-consuming initial configuration and features quite low scanning velocity. In this paper we present a new dynamic mode in which the cantilever gets excited by a feedback loop containing a saturation function. The proposed scheme is then analysed in the frequency domain and simulated against the standard set-up, showing good performance and elimination of some of the known drawbacks. Preliminary results in experiments confirm the effectiveness of this operating mode.
Iris type:
01.01 Articolo in rivista
List of contributors:
Tiribilli, Bruno; Vassalli, Massimo
Published in: