SEISMIC RESPONSE OF An EXISTING R/C SCHOOL BUILDING EQUIPPED WITH A NON- INVASIVE EXTERNAL VISCOUS DAMPING SYSTEM

Conference Paper
Publication Date:
2020
abstract:
The aim of this research is to evaluate the effectiveness of a seismic retrofit technique that in-volves the introduction of energy dissipation devices properly connected to an existing structure through a system of cables and leverisms, which are employed to amplify total or inter-story drift at device end. One of the main topics related to the introduction of energy dissipation de-vices, lies in the choice of their optimal setting within the structure to maximize the effectiveness without producing functionality limitations. The achievement of these objectives is therefore linked, regardless of the type adopted, to the amount of energy dissipated in each cycle, directly proportional to the displacements magnitude to which the device is subject. Many configura-tions proposed in the literature and currently adopted in professional practice provide addi-tional dissipation systems variously connected to braces installed inside the structural frame and therefore able to exploit the inter-story drift produced by seismic input. The proposed sys-tem exploits top displacements of the structure with respect to the foundation level, transferred to the device through a system of cables properly configured and amplified with leverage. This paper represents the first step of the research, in which after a brief description of equation of motion for a simple SDOF system, it is take into account a existing RC school building in Italy to assess performances of the retrofitted structure equipped with the proposed system.
Iris type:
04.01 Contributo in Atti di convegno
Keywords:
existing building; retrofit; dissipation; viscous damper device; school building
List of contributors:
Sabino, Antonio; Mannella, Antonio
Authors of the University:
MANNELLA ANTONIO
Handle:
https://iris.cnr.it/handle/20.500.14243/380387