Design of Grid-Side Electromagnetic Interference Filters in AC Motor Drives with Motor-Side Common Mode Active Compensation
Academic Article
Publication Date:
2009
abstract:
The aim of this paper is to analyze how the introduction
of a motor-side common mode (CM) active filter, in a power
drive system, influences the CMdisturbance propagation. A circuit
model of the whole drive, including the active filter, is used as an investigation
tool. The accuracy of all simulated results is validated
by experimental measurements. Both the electromagnetic interference
(EMI) toward the grid and the internal CM disturbance
propagation are analyzed. These phenomena are compared when
the power drive system is operated bothwith and without the active
filter at the inverter output. An additional effect of the motor-side
CM active filter is a slight reduction of EMI toward the grid at
lower frequencies. This condition allows a reduction in the size of
the power gridCMEMI filter necessary to achieve electromagnetic
compatibility requirements compliance for the drive.
Iris type:
01.01 Articolo in rivista
List of contributors:
Vitale, Gianpaolo; DI PIAZZA, MARIA CARMELA; Ragusa, Antonella
Published in: