Water recovery from humidified waste gas streams: Quality control using membrane condenser technology

Articolo
Data di Pubblicazione:
2014
Abstract:
In this work "membrane condenser" is utilized for the selective recovery of evaporated waste water from industrial gases and for the control of the composition of the recovered liquid water. A simulation study of the process has been developed for predicting the membrane-based process performance. The achieved results indicate that feed flow rate(QFeed), interfacial membrane area(AMembrane), the ratio QFeed/AMembrane, the temperature difference between the fed flue gas Tfeed and the membrane module are the parameter s controlling the process. In particular, the amount of recovered water rises at increasing T and QFeed/AMembrane, where as its quality is made worse at increasing T and QFeed. The data obtained have been also supported by an experimental study of the process, confirming the validity of the simulation study and its suitability for a screening of the operative conditions to be chosen in a membrane condenser.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Dehydration of gaseous streams; Membrane condenser; Water quality
Elenco autori:
Brunetti, Adele; Macedonio, Francesca; Drioli, Enrico; Cersosimo, Maurizio; Barbieri, Giuseppe
Autori di Ateneo:
BARBIERI GIUSEPPE
BRUNETTI ADELE
MACEDONIO FRANCESCA
Link alla scheda completa:
https://iris.cnr.it/handle/20.500.14243/262153
Pubblicato in:
CHEMICAL ENGINEERING AND PROCESSING