Performance analysis of a biomass powered micro-cogeneration system based on gasification and syngas conversion in a reciprocating engine
Articolo
Data di Pubblicazione:
2018
Abstract:
The present paper describes an experimental characterisation of a biomass powered micro-cogeneration system
based on the coupling between a gasifier and an internal combustion engine. The ECO 20 unit is sized to deliver a
maximum electrical and thermal power of 20 kWe and 40 kWth, respectively. In order to highlight possible
inefficiencies along the biomass-to-energy conversion chain, the global energy balance of the system under real
working conditions is derived. Ultimate and proximate analyses of the processed biomass are performed, accompanied
by temperature and mass flow rate measurements and gas chromatograph characterization of collected
samples of the produced syngas. The greatest inefficiency is found in the gasification section with a value
of the cold gas efficiency in the range of 57-60%. The low quality of the syngas (lower heating value equal to
3731 kJ/Nm3) affects the engine combustion efficiency, hence its electrical efficiency that does not exceed
22.5%. The global electrical efficiency of the plant is equal to about 13.5%. As a further analysis, waste heat
recovery is considered under different conditions by decreasing the temperature of the water flowing in the
secondary circuit from 68.35 °C to 20.50 °C for the use of the provided thermal energy. This determines an
increase of the thermal efficiency of the engine from 11.3% to 56.2%, while the global thermal efficiency increases
from 6.46% to 33.72%. A feature of the ECO 20 system is the cooling of the syngas delivered to the
engine by its same cooling water, for a considerable advantage on volumetric efficiency with respect to other
analogous systems, also in the cases the thermal power is not utilised.
based on the coupling between a gasifier and an internal combustion engine. The ECO 20 unit is sized to deliver a
maximum electrical and thermal power of 20 kWe and 40 kWth, respectively. In order to highlight possible
inefficiencies along the biomass-to-energy conversion chain, the global energy balance of the system under real
working conditions is derived. Ultimate and proximate analyses of the processed biomass are performed, accompanied
by temperature and mass flow rate measurements and gas chromatograph characterization of collected
samples of the produced syngas. The greatest inefficiency is found in the gasification section with a value
of the cold gas efficiency in the range of 57-60%. The low quality of the syngas (lower heating value equal to
3731 kJ/Nm3) affects the engine combustion efficiency, hence its electrical efficiency that does not exceed
22.5%. The global electrical efficiency of the plant is equal to about 13.5%. As a further analysis, waste heat
recovery is considered under different conditions by decreasing the temperature of the water flowing in the
secondary circuit from 68.35 °C to 20.50 °C for the use of the provided thermal energy. This determines an
increase of the thermal efficiency of the engine from 11.3% to 56.2%, while the global thermal efficiency increases
from 6.46% to 33.72%. A feature of the ECO 20 system is the cooling of the syngas delivered to the
engine by its same cooling water, for a considerable advantage on volumetric efficiency with respect to other
analogous systems, also in the cases the thermal power is not utilised.
Tipologia CRIS:
01.01 Articolo in rivista
Keywords:
Biomass; Gasification; Micro combined heat and power; Imbert downdraft; Energy balance
Elenco autori:
Costa, Michela
Link alla scheda completa:
Pubblicato in: