abstract:
A theoretical investigation was carried out on the analysis of TPR profiles by the power-law
kinetic model. Attention was focused on the use of the first-order approximation, with the aim to
assess its limits in the procedure for estimating the activation energy of reduction. Numerical
simulations performed by solving the non-isothermal mass-balance equations for the gaseous
and solid species indicated a high sensitivity of the reduction patterns to the reaction order with
respect to the solid. This quantity was found to exert a considerable influence on both the
temperature at peak maximum and the peak shape.
A large number of TPR profiles was generated, assuming reaction orders other than unity and
activation energies ranging from 80 to 100 kJ mol- 1. These profiles were interpreted by means of
the first-order power-law model. The results obtained showed that the unjustified assumption of
the first-order approximation may introduce significant errors in the estimate of the activation
energy. In several cases, real and estimated values differed by more than 30%. In order to provide
some guidelines for a correct kinetic analysis, the causes responsible for such misinterpretation
were investigated from both a qualitative and quantitative point of view.
Iris type:
01.01 Articolo in rivista
Keywords:
Kinetic analysis; Power-law model; Reduction kinetics; Temperature-programmed Reduction